The CTM-ONE supports supply voltages ranging between 7 VDC and 32 VDC. It has two power modes:
Mode | Current @ 12V | Description | Mode change event |
Standby | 0.1-3.3mA | Device is in low power standby mode; |
Operating system is in standby mode for quick boot and modem can wake up on a timer or motion detection. | The device will spend most of its time in this mode, triggers such as timer |
or |
ignition state change will bring the device out of this mode into Operating System mode. | ||
Operating | 80-100 mA | In this mode the device is transmitting/receiving data |
Power consumption in this mode varies based on modem workload and radio network coverage. |
Power management is controlled either by ignition or CAN Bus. By default, the CTM-ONE remains powered on continuously when connected to external power with power management disabled.