Power Management

Power Management

The CTM-400N wireless gateway has three power modes:

 Mode

Current @ 12V

Description

Mode change event

Standby

2 mA

Device is in low power mode with wakeup.

 

The device may spend most of its time in this mode, various configurable triggers will bring the device out of this mode into Operating Mode.

Operating

300mA

Device fully operational.

 

The device will go back into standby mode when the ignition/standby signal is deactivated or upon expiry of the power ON timer if configured.

Off

10uA

Device is in minimal power.

The device draws power from internal battery with wake only when external DC is restored.

Power management is controlled either by ignition line. The default configuration of the CTM-400N is to stay powered on continuously when connected to external power.

NOTE: The CTM-400N has an internal rechargeable battery for short-term power use in the case power is lost from the connection (up to 5 hours of battery life).