All LEDs remain off when the device is powered ON | |
PWR LED flashing | The device is in standby mode Ensure the standby signal is connected to greater than 9 VDC Ensure the supply voltage is greater than 9 VDC.
|
PWR LED ON all other LED OFF | |
Device is constantly rebooting every 4 minutes with no user input. Only PWR LED and GPS LED (solid or flashing) are on. | Incorrect cellular device is configured. The CTM-ONE is configured by default to auto connect to a cellular network. If the CTM-ONE determines that communication with the internal cellular radio module or device is not working, it will attempt to reset the communication port; this will result in continual system reboots if incorrect module/device is selected.
|
GPS LED flashing | No valid GPS fix. The GPS(GNSS) antenna requires a clear view of the sky to obtain a valid GPS fix. The time to fix can vary from a few seconds to several minutes depending on conditions. GPS(GNSS) LED flashing has no impact on cellular connectivity.
|
Cellular LED OFF | RF signal may not be available; CTM-ONE is located in an area of no cellular activity. Cellular device is not registered on the network; make sure radio module/device/SIM has been activated on the network. Incorrect configuration of internal radio module,
|