Please connect the CTM-500 to a suitable power supply. There are three options for powering the CTM-500:

  • DC Power supply (refer to appendix for more detail)

  • Power over Ethernet (PoE)

  • Vehicle ECU (OBDII/J1939)

DC Power Supply

Power for the CTM-500 can be sourced through an AC/DC wall adapter for continuous operation. Alternatively, a DC power cable can connect to a DC power source within the range of 7-32 VDC. Moreover, ignition line detection is supported, allowing the CTM-500 to transition into standby/suspend modes for low-power scenarios.

Simply connect an appropriate power source to the 4-pin locking connector marked with the power icon (blue star) .

 

DC Power Cable Part Numbers:

Length

Part Number

3m (10ft)

6954.2063

4m (13 ft)

6954.2000

4.5m (15 ft)

6954.2031

AC Wall Adaptor Part Number:

Item

Part Number

CTM-ONE/500 AC wall adaptor

6954.2019

Power over Ethernet (PoE)

Power for the CTM-500 can be provided via a compatible PoE (802.3 at) power supply. Simply connect the PoE power supply to the ETH0 port of the CTM-500.

Note: PoE functionality is available on the CTM-500 only when the optional battery pack module is installed.

Item

Part Number

Accessory Battery Pack

11220.9910

Vehicle ECU (OBDII/J1939)

For mobile applications, the CTM-500 can be powered using the vehicle ECU.

Cable Part Numbers:

Length

J1939 Part Number

OBDII Part Number

2m (6ft)

6954.2002

6954.2001

4.5m (15 ft)

6954.2029

6954.2028

6m (20 ft)

6954.2044

Ignition Cable (optional)

Ignition cable is only required for vehicles that cannot determine the ignition state from the vehicle ECU. Please contact Cypress Solutions at support@cypress.bc.ca for additional information.

Length

Part Number

4.5m (15 ft)

6954.2052