The CTM-ONE will be ready for access and configuration approximimately 50 seconds after applying power.
After adding power the CTM-ONE power LED will be solid green and while booting the 4 remaining LED’s will flash in in a left to right pattern of blinking RED LED’s. Once the blinking stops the modem can be accessed
The wireless gateway can be configured via Ethernet or Wi-Fi, provided it is enabled. Depending on the initial configuration upon shipment, this step may be optional. Additionally, all configurations can be remotely executed via the Cypress IOT device management platform.
...
...
...
...
There are two methods for controlling and configuring the CTM-ONE modem. The two methods are local access via web browser and remote access via our device management platform: Cypress IOT.
Cypress IOT solution is a secure, multi-tenant platform that allows you to manage, deploy, and monitor devices in one place. As a scalable cloud-based application, you can configure devices, schedule tasks, and automate processes from your desktop, tablet, or smartphone.
Local Access via web browser (interface)
Configuration of the CTM-ONE modem is achieved through a hierarchical web GUI interface. Cypress IOT provides the same hierarchical interface to replicate the experience of being locally connected to the device.
Local Access:
Connect locally to the modem via Ethernet cable or Wi-Fi.
Available even when the modem does NOT have an active cellular connection or no SIM installed.
Local Access Prerequisites:
Physical access to the CTM-ONE device.
Modem must be configured to accept connections via local Ethernet or Wi-Fi.
The connecting computer must allow connections via the LAN/WLAN configuration on the modem.
Remote Access via Cypress IOT
Devices regularly "check-in" to Cypress IOT at user-configurable time intervals, such as every 900 seconds or 15 minutes. Device management via Cypress IOT is a near real-time system for device management based on the programmed check-in time. After a device checks in to Cypress IOT, it will apply any configuration changes queued for the device via the configuration/command/jobs interface of Cypress IOT.
Remote Access Prerequisites:
Users must have active Cypress IOT credentials.
Modem must be able to communicate with Cypress IOT via cellular wireless connection.