Molex Micro-Fit 3.0™ connector #:
Part Number | Description |
---|---|
43025-0400 | Receptacle housing |
43030 | Crimp Terminals 20-24 AWG |
The CTM-ONE can be connected using a DC power cable (see available options below) for direct connection to a DC power supply. Alternatively, it can be connected with an optional AC Wall Plug adapter , facilitating (PN: 6954.2019) that allows quick and easy connection to a standard 120V AC power outlet.
...
Power.
Below are the available part numbers for DC power cable options:
6954.2000 (13ft)
6954.2020 (3ft)
6954.2031 (15ft)
...
Red | +7V to +32V DC |
---|---|
Black | 0V return (GND) |
White | Standby / Ignition (+V for operation, off for standby) |
...
Reporting and logging of Ignition ON/OFF events.
Activation of shutdown based on a timer, such as turning off the CTM-ONE ten minutes after ignition has been turned off.
Power (Not Required if Regular* OBDII/J1939 Cables Used)
*Separate DC power is not required if one of the following OBDII/J1939 cable part numbers is used:
6954.2001
6954.2002
6954.2028
6954.2029
6954.2044
To enable the “ignition sense” feature, a separate ignition cable (PN: 6954.2052) is required. Simply plug this cable into the CTM-ONE’s power port, contact Cypress Solutions Technical Support and an updated configuration will be pushed through to enable the ignition-based power management.
Note |
---|
Before connecting any external cables (GPS, Cellular RF, Wi-Fi RF, WPAN RF, serial, Ethernet, GPIO, CAN), ensure that the power cable is correctly wired on the battery side. In some instances, connecting the battery input in reverse may result in damage that is not covered under warranty. |