Part Number | Description |
---|---|
43025-0400 | Receptacle housing |
43030 | Crimp Terminals 20-24 AWG |
The CTM-500 ONE can be connected using a DC power cable for direct connection to a DC power supply. Alternatively, it can be connected with an optional AC Wall Plug adapter, facilitating quick and easy connection to a standard 120V AC power outlet.
...
A 5 Amp “slow-blow” fuse is recommended in the +V supply line.
Operation/Standby Line
When the operate/standby line is utilized, the CTM-ONE can leverage the state of this line through its "ignition sense" features. Even when the ignition line is wired, the CTM-ONE does not completely shut down; instead, it consumes a minimal amount of power (ranging from 1.2mW to 40mW) to monitor the status of various inputs. This allows the device to "wake on events" that occur while in low power mode.
Advantages of connecting power using the vehicle's operate/standby or ignition line .include:
Reporting and logging of Ignition ON/OFF events.
Activation of shutdown based on a timer, such as turning off the CTM-ONE ten minutes after ignition has been turned off.
Note |
---|
Before connecting any external cables (GPS, Cellular RF, Wi-Fi RF, WPAN RF, serial, Ethernet, GPIO, CAN), ensure that the power cable is correctly wired on the battery side. In some instances, connecting the battery input in reverse may result in damage that is not covered under warranty. |