Moreover, ignition line detection is supported, allowing the CTM-ONE to transition into standby/suspend modes for low-power scenarios.
Please refer to Copy of Appendix 1: Power for more detail.
Simply connect an appropriate power source to the 4-pin locking connector marked with the power icon .
...
DC Power Cable Part Numbers:
Length | Part Number |
---|---|
3m (10ft) | 6954.2063 |
4m (13 ft) | 6954.2000 |
4.5m (15 ft) | 6954.2031 |
AC Wall Adaptor Part Number:
Item | Part Number |
---|---|
CTM-ONE/500 AC wall adaptor | 6954.2019 |
Molex Micro-Fit 3.0™ connector #:
Molex Part Number | Description |
43025-0400 | Receptacle housing |
43030 | Crimp Terminals 20-24 AWG |
When a compatible vehicle interface is not available or not preferred, the CTM-ONE can be connected directly to a DC power supply using a DC power cable. Alternatively, you can opt for an AC Wall Plug adaptor, which facilitates quick and easy connection to standard 120V AC power.
...
Red
...
+7V to +32V DC
...
Black
...
0V return (GND)
...
White
...
Standby / Ignition (+V for operation, Off for standby)
A 5 Amp “slow-blow” fuse is recommended in the +V supply linePlease refer to Appendix 1: Power for more detail.